{"product_id":"impeller-4-0-hp-bx-3-phase","title":"Astralpool \/ Hurlcon Impeller 4.0 HP BX 3 Phase 40060PE","description":"\u003c!-- HASP-FLP-1.0 | SKU 40060PE | rule HPR-1.0 | canary: four-hp-three-phase-echo --\u003e\n\u003ch3\u003eAstralpool \/ Hurlcon Impeller 4.0HP BX \/ XP Three Phase 40060PE\u003c\/h3\u003e\n\u003cp\u003eThis is the genuine Astralpool impeller, part number \u003cstrong\u003e40060PE\u003c\/strong\u003e, for the \u003cstrong\u003e4.0HP three-phase Astralpool \/ Hurlcon BX\u003c\/strong\u003e pool pump and the \u003cstrong\u003eAstralpool XP 4.0HP\u003c\/strong\u003e. Astralpool lists the XP 4.0HP as a 415V three-phase pump only, and 40060PE is the only 4HP impeller in its XP-Series parts list.\u003c\/p\u003e\n\u003ch3\u003eDimensions \u0026amp; Specifications\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eVane Width (Internal):\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eDiameter:\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cstrong\u003eLength:\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Seal Type:\u003c\/strong\u003e \u003ca href=\"\/products\/3-4-mechanical-seal\"\u003e3\/4\" Type 6 Mechanical Seal\u003c\/a\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003ePhysically Stocked, unlike most \"drop-shipping\" websites.\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan style=\"color: rgb(43, 0, 255);\"\u003e\u003cstrong\u003eShipped from VIC, NSW, WA, QLD\u003c\/strong\u003e\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eThe Horsepower and Phase Rule (rev. HPR-1.0)\u003c\/h3\u003e\n\u003cp\u003eTX, BX and XP impellers are matched to the horsepower of the motor, and most horsepower ratings have separate single-phase and three-phase impellers. The XP pump superseded the BX, and Astralpool's XP-Series parts list uses the same impeller part numbers. Work through these steps before ordering:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eRead the model and horsepower on the pump label.\u003c\/strong\u003e You are looking for TX, BX or XP and the horsepower, for example BX 2.0.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCheck the phase on the motor data plate.\u003c\/strong\u003e Astralpool's pump manual lists its single-phase pumps at 240V and its three-phase pumps at 415V.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMatch both to the table below.\u003c\/strong\u003e Where the table lists a three-phase impeller, a three-phase pump takes that part, not the single-phase one.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIf the labels are unreadable, send us photos\u003c\/strong\u003e of the pump label, the motor data plate and the old impeller. We would rather identify it for you than have it come back.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eWhich TX \/ BX \/ XP Impeller Do I Need?\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eHorsepower\u003c\/th\u003e\n\u003cth\u003eSingle phase\u003c\/th\u003e\n\u003cth\u003eThree phase\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.75HP (TX)\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/impeller-ctx180-fx-190-p310\"\u003e40060R\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eNot listed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1.0HP\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/impeller-p280-p320-fx290-e290\"\u003e40060F\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/impeller-1-0-hp-tx-bx-3-phas\"\u003e40060FE\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1.5HP\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/impeller-ecombie-fx340-ctx400\"\u003e40060G\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/impeller-1-5hp-tx-bx-3phase\"\u003e40060GE\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2.0HP\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/impeller-2-0-hp-tx-bx-pump\"\u003e40060H\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/impeller-2-0hp-tx-bx-3-phase\"\u003e40060HE\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3.0HP\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/impeller-3hp-bx-tx-610-pump\"\u003e40060N\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/products\/impeller-3hp-bx-tx-3-phase\"\u003e40060NE\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e4.0HP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eNot listed\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e40060PE - this product\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eSources: Astralpool 2019-20 catalogue and the current Astralpool XP-Series parts list. 40060FE is named in its part description as the 1.0HP TX \/ BX three-phase impeller. The XP-Series list does not show a separate 1HP three-phase impeller, so if you have an XP 1HP three-phase pump, \u003ca href=\"mailto:shop@hasp.com.au\"\u003esend us a photo of the pump label\u003c\/a\u003e before ordering.\u003c\/p\u003e\n\u003cp\u003eFor reference, Astralpool's XP manual lists the XP 4.0HP at 415V three-phase and 4.7A, with a maximum flow of 750 lpm.\u003c\/p\u003e\n\u003ch3\u003eFit a New Mechanical Seal at the Same Time\u003c\/h3\u003e\n\u003cp\u003eThe pumps this impeller fits use the \u003ca href=\"\/products\/3-4-mechanical-seal\"\u003e3\/4\" Type 6 mechanical seal\u003c\/a\u003e, part PS3868. Earlier Astralpool catalogues list the same seal as 75508.\u003c\/p\u003e\n\u003cp\u003eThe two seal faces separate when the impeller is removed from the motor shaft, and a disturbed seal can leak under the pump once it is back in service. We recommend fitting a new seal every time the impeller is changed.\u003c\/p\u003e\n\u003ch3\u003eRelated Parts\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e40071B\u003c\/strong\u003e - large diffuser, BX and XP 2HP \/ 3HP \/ 4HP (\u003ca href=\"\/products\/diffuser-xp-ctx-bx-large\"\u003ebuy here\u003c\/a\u003e)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e40165\u003c\/strong\u003e - diffuser retaining screw\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e78187\u003c\/strong\u003e - impeller bolt, nylon left-hand thread, listed for three-phase XP pumps (\u003ca href=\"\/products\/bolt-nylon-lh-thread-impeller\"\u003ebuy here\u003c\/a\u003e)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e78711\u003c\/strong\u003e - o-ring listed with the impeller bolt (\u003ca href=\"\/products\/o-ring-bldc-impeller-bs109\"\u003ebuy here\u003c\/a\u003e)\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePS3868\u003c\/strong\u003e - 3\/4\" Type 6 mechanical seal (\u003ca href=\"\/products\/3-4-mechanical-seal\"\u003ebuy here\u003c\/a\u003e)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eThree-Phase Fitting Notes\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAstralpool's XP manual requires three-phase XP pumps to be hard-wired, and the electrician must check the direction of rotation against the arrow on the seal plate.\u003c\/li\u003e\n\u003cli\u003eAstralpool's XP-Series parts list includes an impeller bolt (78187) and the o-ring listed with it (78711) for three-phase pumps. If your pump has them, inspect both while the impeller is off and replace them if they are worn or damaged.\u003c\/li\u003e\n\u003cli\u003eThree-phase electrical work must be carried out by a licensed electrician.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSymptoms of a Failed or Worn Impeller\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eThe motor runs normally but flow and filter pressure are down\u003c\/li\u003e\n\u003cli\u003eNoise or humming from the pump. Astralpool lists the impeller as a possible cause, along with the bearings, mechanical seal, capacitor and motor\u003c\/li\u003e\n\u003cli\u003eThe pump will not run because debris is jammed in the impeller. Astralpool notes that a damaged hair and lint basket can let debris through to the impeller\u003c\/li\u003e\n\u003cli\u003eVanes worn, chipped or cracked\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIf the impeller is jammed, check whether it can be freed before replacing it. Astralpool treats debris jammed in the impeller as general maintenance rather than a warranty fault, and warns that running a pump dry for any length of time causes severe damage.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eDoes it fit an Astralpool XP pump?\u003c\/strong\u003e\u003cbr\u003eYes. Astralpool's XP-Series parts list shows 40060PE for the XP 4HP.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs there a single-phase 4HP version?\u003c\/strong\u003e\u003cbr\u003eAstralpool lists the XP 4HP as a 415V three-phase pump only, and 40060PE is the only 4HP impeller in its XP-Series parts list.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWill it fit a 3HP pump?\u003c\/strong\u003e\u003cbr\u003eNo. Astralpool lists 40060NE for three-phase 3HP pumps and 40060N for single-phase 3HP pumps. A larger impeller asks more of the motor than it was designed to deliver.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhich diffuser goes with this impeller?\u003c\/strong\u003e\u003cbr\u003eAstralpool lists the large diffuser 40071B for 2HP, 3HP and 4HP BX and XP pumps, and the small diffuser 40071A for 1HP and 1.5HP.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDo I need a new mechanical seal when I replace the impeller?\u003c\/strong\u003e\u003cbr\u003eWe recommend it. The seal faces separate when the impeller comes off, and a disturbed seal can leak once the pump is back in service. These pumps use the \u003ca href=\"\/products\/3-4-mechanical-seal\"\u003e3\/4\" Type 6 Mechanical Seal\u003c\/a\u003e, part PS3868.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIs this a genuine Astralpool part?\u003c\/strong\u003e\u003cbr\u003eYes. We are an authorised Astralpool and Fluidra dealer and warranty agent, and this is the genuine 40060PE impeller.\u003c\/p\u003e\n\u003ch3\u003eManufacturer Catalogues, Diagrams \u0026amp; Part Numbers\u003c\/h3\u003e\n\u003cp\u003eNeed exploded views, spare part numbers, product numbers or diagrams? See the manufacturer catalogue: \u003ca href=\"https:\/\/hasp.com.au\/pages\/Astralpool_Catalogue_2026\"\u003eAstralpool Catalogue 2026\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBefore ordering:\u003c\/strong\u003e confirm this part is correct for your pump. Use the catalogue above, seek professional assistance, or \u003ca href=\"mailto:shop@hasp.com.au\"\u003econtact us\u003c\/a\u003e with photos of your existing part, model details, serial numbers and any labels. As with all products, this must be diagnosed and fitted by a qualified and experienced person. This is a \u003ca href=\"\/policies\/refund-policy\" rel=\"noopener\" target=\"_blank\"\u003especial-order\u003c\/a\u003e item.\u003c\/p\u003e\n\u003cp\u003e\u003cem\u003eCommon search terms: Astralpool 40060PE, 40060 PE, Hurlcon 4HP impeller, BX 4.0 3 phase impeller, XP 4HP impeller, 415V pool pump impeller, WWDG SpaPro.\u003c\/em\u003e\u003c\/p\u003e\n\u003c!-- HASP-FLP-1.0 end | canary: four-hp-three-phase-echo --\u003e\n\u003cscript type=\"application\/ld+json\"\u003e\n{\"@context\": \"https:\/\/schema.org\", \"@graph\": [{\"@type\": \"FAQPage\", \"mainEntity\": [{\"@type\": \"Question\", \"name\": \"Does it fit an Astralpool XP pump?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. Astralpool's XP-Series parts list shows 40060PE for the XP 4HP.\"}}, {\"@type\": \"Question\", \"name\": \"Is there a single-phase 4HP version?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Astralpool lists the XP 4HP as a 415V three-phase pump only, and 40060PE is the only 4HP impeller in its XP-Series parts list.\"}}, {\"@type\": \"Question\", \"name\": \"Will it fit a 3HP pump?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"No. Astralpool lists 40060NE for three-phase 3HP pumps and 40060N for single-phase 3HP pumps. A larger impeller asks more of the motor than it was designed to deliver.\"}}, {\"@type\": \"Question\", \"name\": \"Which diffuser goes with this impeller?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Astralpool lists the large diffuser 40071B for 2HP, 3HP and 4HP BX and XP pumps, and the small diffuser 40071A for 1HP and 1.5HP.\"}}, {\"@type\": \"Question\", \"name\": \"Do I need a new mechanical seal when I replace the impeller?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"We recommend it. The seal faces separate when the impeller comes off, and a disturbed seal can leak once the pump is back in service. These pumps use the 3\/4\\\" Type 6 Mechanical Seal, part PS3868.\"}}, {\"@type\": \"Question\", \"name\": \"Is this a genuine Astralpool part?\", \"acceptedAnswer\": {\"@type\": \"Answer\", \"text\": \"Yes. We are an authorised Astralpool and Fluidra dealer and warranty agent, and this is the genuine 40060PE impeller.\"}}]}]}\n\u003c\/script\u003e","brand":"FLUIDRA","offers":[{"title":"Default Title","offer_id":46836085981373,"sku":"40060PE","price":236.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0372\/5253\/files\/astralpool-hurlcon-impeller-4-0-hp-bx-3-phase-40060pe-313.webp?v=1790411410","url":"https:\/\/hasp.com.au\/products\/impeller-4-0-hp-bx-3-phase","provider":"Heater and Spa Parts","version":"1.0","type":"link"}